  • HSI Test Fixture

    TA-552 - Tech-Aid Products

    This test fixture provides the necessary panel controls, switching and cable pin-outs required to test the KPI-552/KPI-553/A series of HSI's as described in their respective maintenance manuals. This fixture will serve as the "Instrument Bench Tester" and does have the required differential resolvers and relay switching. Panel jacks are provided for the Heading, Course, RMI and ADF synchro sources that are external to this fixture. The use of external synchro sources serves to minimize the cost of this panel. Additional items incorporated on the panel are test jacks to monitor the meter drive voltage and current as well as a momentary switch to open the meter drive and this serves to verify sticky meter stops. The fixtures rear panel provides for all power inputs as well as an I/O connector if the shop desires to interface an external synchro panel.

  • SFP Based Fiber Optic Test Solution

    Eye-BERT Micro - Spectronix

    The Eye-BERT Micro is a low cost, easy to use, all-in-one SFP based fiber optic test solution offering high performance bit error rate testing at a fraction of the cost while providing a rich set of features not found in other bit error rate testers. Features include: variable bit rate, user programmable patterns, and optical power and temperature monitoring (per SFP capability). Additionally, with a click of a button, the Eye-BERT Micro will automatically test an SFP module based on the information it reads from the module and generate a detailed test report complete with manufacturer, part number, serial number, date code, fiber type, link length, speed, and test results. The Unit is supplied with anti-skid bumpers and is small enough to be integrated into larger systems for dedicated link verification.

  • Medical Leakage Current Tester

    2675Y - Shenzhen Chuangxin Instruments Co., Ltd.

    The 2675Y Medical Leakage Current Tester Series Is The Test Equipment Used For Measuring Continuous Leakage Current And Patient Auxiliary Current Of Medical Electrical Equipment.It Designs And Products According To The GB9706.1_2020 (IEC60601-1:2012) .And The Test Circuit (MD)Input Impedance To Simulate The Body Impedance,It Accord With The Requirements Of GB9706.1-2020 (IEC60601-1:2012),The Test Current Can Run Up To 5A,And Provide Users With An Isolation Power Supply Which Adjustable Output Voltage For 0~250V Continuously Of The Basic Capacity Configuration For The 500VA And Provide Another 110% Voltage Source Of The Maximum Rated Voltage.It Can Satisfy The I,II, Various Types Of Equipment Test The Earth Leakage Current,Shell Leakage Current,Patient Leakage Current,Patient Auxiliary Leakage Current Under Normal Condition And The Single Fault.

  • Advanced Cable Tester v2

    TP800110 - Total Phase Inc.

    The Total Phase Advanced Cable Tester v2 is the quickest and most convenient way to comprehensively test USB, Lightning, and video cables. It provides:*Short testing - Dynamic visualization of test results*Open testing - Dynamic visualization of test results*Continuity testing - Dynamic visualization of test results*DC resistance measurement for most wires, with milliohm precision on ground and power wires, ohm resolution on most other wires, continuity check only on high-speed data lines*Signal integrity testing of data lines to 12.8 Gbps per channel*E-Marker verification*Lightning plug bring up/function (Apple Lightning Cables)**Over-voltage protection (Apple Lightning Cables)**Voltage recovery testing (Apple Lightning Cables)**Quiescent current consumption (Apple Lightning Cables)*

  • Turns Ratio Testers

    TRT Standard Series - IBEKO Power AB

    When it comes to choosing a transformer turns ratio tester, TRT Standard series offers some of the most advanced instruments with LCD display out in the market. Each model measures transformer excitation current and phase shift performs automatic vector group detection and magnetic balance on three-phase transformers and three-phase autotransformers. Furthermore, they have a built-in true three-phase power source. Because of that, TRT Standard instruments can test transformers with special configurations, such as phase-shifting, rectifier, arc-furnace, traction transformers, etc.The instruments can output test voltages from 1 V AC to 250 V AC, depending on the chosen model. High test voltage of 250 V AC provides more accurate turns ratio testing compared to other turns ratio testers on the market and extremely low test voltage of 1 V AC enables turns ratio verification of current transformers.TRT Standard series consists of:TRT03 Models (TRT03A, TRT03B, TRT03C) – single-phase voltage up to 100 VTRT3x Models (TRT30A, TRT30B, TRT30C, TRT33A, TRT33B, TRT33C) – single and true three-phase voltage up to 100 VTRT63 Models (TRT63A, TRT63B, TRT63C) – single and true three-phase voltage up to 250 VMore about models differences can be found under the downloads tab, in brochures and comparison sheets.A user can create test templates using the DV Win software and store them in the PC’s memory for later use when in the field.TRT Standard series models have a built-in tap changer control unit. Consequently, it enables remote control of an on-load tap changer (OLTC) directly from the tester. In order to make the most out of this feature, the DV-Win software can be programmed to do everything automatically – running turns ratio tests, changing OLTC tap positions and saving results. This option, especially in combination with test templates, significantly facilitates and shortens the turns ratio testing time.

  • Fully Automatic Transformer Winding Resistance Tester

    Neutronics Manufacturing Co.

    Measure DC resistance of transformers windings etc. Introduction: The NMC ''TDR'' is a high precision, new generation, light weight large output current and micro-processor controlled tester. This replaces old DC wheat stone bridge and double arm bridge for measurement of DC resistance. ''TDR'' adopts new advanced test current power supply technology, four terminal measurement, digital display of resistance value and test current. ''TDR'' is powered by 220V AC mains single phase supply. The measurements are accurate as the test current is highly stable. High automation is achieved with automatic discharge warning.Principle: The constant current generated is fed to the resistance under test through the current terminals and the voltage drop across the resistance under test is measured and displayed in ohms. A true four terminal measurement is used to eliminate the need for lead resistance compensation.

  • Cable Tracers

    162 CB - Standard Electric Works Co., Ltd

    Filter Probe● Works with any Tone Generator to identify wires.● Volume control for increasing sensitivity and adjustable to suit work environment.● 2 operation modes: Filter on / Filter off.● The auto-off function (5 minutes) prevents battery consumption.● Power supply is available in any 9V battery with a life of approximately 50 hours.● A phone jack is designed for headset or handset.● Flashlight function.Tone Generator● Tone Generator is a great tool for locating and identifying cable pairs or individual conductors.● 162 CB-G doesn't only provide the function of a tone generator, but also serves as a continuity and polarity tester.● A tone selector switch located inside the unit for selection of the fast tone or the slow tone.● Two bi-colored LEDs for Line1 and Line 2 indication of the polarities of the telephone lines.● The unit has alligator type terminals, a modular cable of 4 conductors with a strong connector.● The tone and continuity functions are only applied to Line1. (Modular connector)

  • Digital Leakage Current Tester

    Educated Design & Development, Inc.

    Fast - All operator controls are located on the front panel to expedite testing. The entire test can be performed in a matter of seconds! Pays for itself in time and stress savings. Versatile - Measures Leakage Current in accordance with UL, CSA, EN, and IEC/ International Standards. Includes ability to perform open neutral, open ground, and line polarity forward/reverse test conditions. Adaptable - Universal rear panel receptacle allows for testing products with any plug configuration. Accurate - True RMS meter accurately measures both sinusoidal and non-sinusoidal waveshapes. This is important when testing products using a switch mode power supply which can generate non-sinusoidal leakage currents. Calibrated, traceable to NIST. Flexible - A front panel switch permits testing either through the power cord of the product under test, from surface/ patient connection-to-ground, or from surface/ patient connection-to-surface/ patient connection. Portable - Lightweight, with integral handle. Other Features - Product Ground Switching (grounding conductor maintained to device under test when not measuring leakage). Automatic front receptacle disconnect when configured in the 240V test mode (prevents inadvertent connection of 120V when configured for 240V operation). Proven - These are the only leakage current testers designed and supported by Product Safety experts. That is part of the reason why they have become the standard in the industry. Full technical support by experienced safety engineers.

  • AMIDA 3001XP Tester

    Amida Technology, Inc.

    AMIDA has introduced two new analog/mixed-signal and logic options in the AMIDA-3000 series in recent years—the AMIDA-3001XP and AMIDA-3KS test systems. Both reinforce the AMIDA-3000 series' ability to provide cost-optimized test solutions for a variety of consumer components in power management and mobile device components. The AMIDA-3000 series provides more than twice the number of analog channels of its modules per test system, thus greatly reducing the acquisition cost of each channel and more than doubling the number of analog channels in the entire test system. This results in a higher number of parallel tests and a higher level of capability for this system, as well as a lower and more cost-effective IC unit test cost for this tester. This series of test systems provides a powerful test combination with high-speed hardware and software integration. The built-in instant messaging protocol detection function of AMIDA-3001XP test machine not only simplifies the complexity and difficulty of test development, but also greatly shortens the test time by using its high-speed computing capability.

  • Combination Board Tester

    ATE QT2256-640 PXI - Qmax Test Technologies Pvt. Ltd.

    Most commercial ATEs does only functional test and do not carry out DC/AC parameter testing, which are very essential in increasing the fault coverage and for achieving near zero field returns. The testing challenges get worse when the boards are equipped with BS compatible components, DSP chips and CPUs or micro controller based boards. ATE QT2256-640 PXI system is designed as a combination board tester capable of testing highly complex and PCBs employing various techniques on a single platform. It can be easily upgraded to 640 digital channels and with programmable UUT power supplies, IEEE or PXI external instrumentation, Bus cycle signature system, ICE and integrated Boundary scan Test AC/DC parametric testing. The ATE is interfaced to an external host PC using a PCI express interface card allowing a maximum data transfer rate. Most commercial ATEs does only functional test and do not carry out DC/AC parameter testing, which are very essential in increasing the fault coverage and for achieving near zero field returns. The testing challenges get worse when the boards are equipped with BS compatible components, DSP chips and CPUs or microcontroller based boards.

  • HBM Verification Tester

    HBM-VT - High Power Pulse Instruments GmbH

    - HBM pulse generator verification tester according ANSI/ESDA/JEDEC JS-001 up to ±10kV- To be used in HBM test and qualification labs for regular pulse generator specification compliance test in order to fulfill lab audit and certification requirements- Fully automatic compliance test and verification of HBM pulse generators regarding ANSI/ESDA/JEDEC JS-001 normative standard at 3 different load conditions: Short Circuit, 500 Ω, and a reference diode at VBR=15 V reverse breakdown voltage, including DC test- Parameter evaluation and verification of the transient HBM current waveforms: Peak Current, Rise Time, Decay Time, Maximum Ringing Current- Optionally available upgrade for all HPPI TLP-3010C, 4010C, 8010A, 8010C, HBM-TS10-A hardware systems in combination with HBM-S1-B (6kV) pulse generators (upgrade on request)- Fully automatic test report generation (PDF)- Electrically floating (no fixed system ground): The HBM loads, current sensor output, USB control interface and the enclosure are electrically floating. There is no limiting system ground which may introduce common-mode interference induced HBM current measurement errors.- Isolated industrial full-speed USB control interface- Isolated power supply derived from USB port- Compact size 126mm x 82.5mm x 44.5mm

  • Leeb Hardness Tester

    THL500 - TMTeck Manufacturing Limited

    It is the highest brightness display in China showing all functions and parameters, easy read Largest screen Oled screen and operate,also can save lots of energy .the largest screen of Leeb hardness tester in China. Two hardness scale dual-display in the screen. Measuring direction in 360 and add the auto measure direction to make test easy and precision. Add four new hardness scales, HRA, HB for D impact device of alloy tool steel; HV for cast aluminum alloy. Add New user material function, to meet the need of user can test the special material. Test at any angle, even upside down. Wide measuring range. It can measure the hardness of all metallic materials. Direct display of hardness scales HRB, HRC, HV, HB, HS, HL and three types of strength values immediately. Seven impact devices are available for special application. Automatically identify the type of impact devices. Large capacity memory could store 600 groups (Relative to average times321 ) information including single measured value, mean value, testing data, impact direction, impact times, material and hardness scale etc. Upper and lower limit can be preset. It will alarm automatically when the result value exceeding the limit. Battery information indicates the rest capacity of the battery and the charge status. User calibration function. USB port with the PC humanity multi-functions data proceeding software. Original imported high speed thermal printer support the immediate printing function. It can save data permanently. Li rechargeable battery as the power source. Charge circuit integrated inside the instrument. Continuous working period of no less than 200 hours (EL off and no printing). Auto power off to save energy. Excellent after-sale service system for high quality products---3 years guarantee and all life maintenance. Easy to buy and comfortable to use.

  • Three-Phase Transformer Winding Resistance Meters

    TWA Standard Series - IBEKO Power AB

    When it comes to winding resistance measurement on three-phase power transformers and autotransformers, TWA Standard series offers some of the most technically advanced instruments with LCD display in the market. Both models are capable of testing six transformer windings with a one-time cable connection, as well as three-phase automatic transformer demagnetization. The stored magnetic energy is safely automatically discharged at the end of the test. The built-in tap changer control unit enables automated test mode, where the instrument operates the tap changer without operator input and records winding resistance results based on pre-selected stabilization criteria. This option makes the operator’s job significantly easier.Both models can output test currents from 5 mA to 25 A DC for the purpose of winding resistance measurement. TWA40D has a special test mode for checking the synchronization of on-load tap changers with three phases simultaneously tested in parallel, in which the total test current can rise to up to 40 A DC.TWA40D has additional advantages when it comes to non-intrusive tap changer analysis. The unique DVtest method enables checking the moving contacts of on-load tap changers during the transition, measuring the transition time, detecting open circuits, and many other types of faults. It is performed with 0.1 ms sampling rate, simultaneously with the measurement of tap changer motor current which helps with the detection of motor and mechanical issues. A special proprietary algorithm is used for testing tap changers connected through a built-in series (booster) transformer. The DVtest can be performed either on one phase or on three phases simultaneously. It can also be performed as an additional test simultaneously with the winding resistance test in all tap positions.An additional unique advantage of TWA40D is the capability of simultaneously testing the winding resistance of all three phases of a three-phase transformer (connected in a YN configuration). This can significantly shorten the total testing time – for example, it enables the operator to perform 33 measurements instead of 99 on a tap changer with 33 tap positions.The test leads for TWA three-phase transformer winding ohmmeters are interchangeable with the TRT turns ratio testers, which means that both sets of tests can be performed with a single test lead connection to the power transformer terminals.

  • Battery Capacity Tester

    BLU-T Series - IBEKO Power AB

    Battery load bank BLU-T is a powerful and lightweight solution designed for condition assessment of telecommunication and radio equipment backup supply. This instrument can perform the battery capacity test on battery strings such as Pb, Li-ion, Ni-Cd, and others. It tests battery strings with voltages in the range of 0,9 – 70,5 V DC. As a special feature, the BLU110T model enables capacity testing of single PB, Ni-based as well as Li cells (with current up to 100 A).The capacity test is conducted in an accurate, user-friendly way. Also, it is in accordance with battery testing standards: IEEE 450-2010, IEEE 1188-2005, IEEE 1106-2015, IEC 60896-11/22, and other relevant standards.BLU-T battery load bank enables setting the discharge current up to 350 A, with 0,1 A resolution. If higher currents are required, the BLU-T units can be connected in parallel, or BXL-T additional load units can be linked.The instrument offers a high power-to-weight ratio. BLU-T series has models starting from 12,8 kg / 28.2 lbs and up to 19,2 kW of power.A user can select one of three discharge modes: Constant current, Constant power, Constant resistance. Additionally, different battery duty cycles can be simulated using user-selectable discharge profiles.Discharge parameters can be monitored in real-time during the capacity test. A 4,3-inch touch screen shows overall battery voltage, discharge current, discharge test time and capacity during the entire test. Also, the capacity tester is compatible with DV-B Win software. A user can view a detailed numerical and graphical presentation of key parameters, and create reports in various formats.Testing can be carried out without disconnecting the battery from the service.